Westermo TDW-33 User Manual

Page 46

Advertising
background image

6618-3202

46

*WIOL – Generic I/O list

Supported by:

TD-36 485

TR-36B

Description:

This command is used to program the list of I/O entries with parameters and data.

Syntax:

AT*WIOL = <entry>,<service>,<flag>,<timeout>,<priority>,<”data1”>,<”data2”>,
<data3>, <data4>,<data5>,<data6>

AT*WIOL = ?

List all table entries. Listing will present a short form table of the

entire I/O list..

AT*WIOL=n?

List all data parameters for a defined entry.

AT*WIOL?

Parameters:

<entry>
I/O entry number, up to 10 entries can be defined.

<service>
I/O entry service

0 = NONE

No service defined for this entry

1 = DIAL

Makes a connection to the number defined in <data1>

2 = SMS

<data1> Destination number of the SMS
<data2> SMS-message.
<data3> SMS service provider number
<data4> SMS protocol type (0 = NONE,1 = UCP,2 = TAP)
<data5> Password if required by provider.

3 = TEXT

Make a connection to number defined in <data1> and transfer text
defined in <data2>.

4 = EMAIL

Reserved for future use, service not implemented

5 = OUT

Make a connection to the number defined in <data1> and set/pulse
the remote output according to pattern defined in string defined in
<data2>. The connection is terminated after the pattern is trans-
ferred.

6 = CMD

AT command specified by <data1> is executed when the entry is
trigged

7 = TRANS

Makes a connection to number defined by <data1>,
I/O is transferred transparently between the two units. The trans-
parent mode must be ended by a timeout.

Advertising