Westermo TDW-33 User Manual

Page 8

Advertising
background image

6618-3202

8

%Cn – Select data compression

Supported by:

TDW-33

TD-36

TD-36 485

TR-36

TR-36B

Description:

This command enables or disables data compression. The modem can only perform data
compression on an error corrected link. The parameter value, if valid, is written to S41
bit 0 and 1.

Syntax:

AT%C<n>

Parameters:

<n>

0: No compression. Resets S46 bit 1.

1:

Enables MNP 5 data compression. Resets S46 bit 1.

2:

Enables V42bis data compression. Sets S46 bit 1

3:

Enables both V.42bis and MNP5 data compression. Sets S46 bit 1. (Default)

Command example

Possible responses

Note

AT%C<n> OK

The command is valid
and accepted

ERROR

Otherwise

S register: The value is written to S41 bits 0 and 1 and S46 bit 1

&Cn – DCD Option

Supported by:

TDW-33

TD-36

TD-36 485

TR-36

TR-36B

Description:

This command controls the DCD output in accordance with the parameter supplied

Syntax:

&C<n>

Parameters:

<n>

0: DCD remains ON at all times

1:

DCD follows the state of a carrier (Default)

Command example

Possible responses

Note

AT&C<n> OK

The command is valid
and accepted

ERROR

Otherwise

S register: The value is written to S21 bit 5