Westermo TDW-33 User Manual

Page 18

Advertising
background image

6618-3202

18

In – Request identification information

Supported by:

TDW-33

TD-36

TD-36 485

TR-36

TR-36B

Description:

This command causes the product to transmit one or more lines of specific information
text.

Syntax:

ATI<n>

Parameters:

<n>
0:

Display max line speed.

1: Reserved
2: Reserved
3: Reserved
4:

Display manufacturer identification.

5:

Display country code.

6:

Display revision identification for modem modulation code

7: Reserved
8: Display switch settings

9:

Display Westermo Application Software revision identification.

Other values: “ERROR” string is sent back.

Command example Possible responses

Note

ATI0

33600

Max line speed

OK

ATI4

WESTERMO

Modem manufactor

TELEINDUSTRI

AB

identifier

OK

ATI6 BSMW310_BF533_bfbsmw310_5457OK

Revision

identification

OK

for modem modula-
tion code

ATI8

000 000 000 000

Switch settings

OK

Each DIP switch
displayed as a decimal
value. S1 S2 S3 S4
Notice switch setting
is only reed at power-
up and ATZ

ATI9 4101-0201

Westermo

SW

OK

release

ERROR

Otherwise

S register: None