*WCID – Caller ID / A-Number

Supported by:

TDW-33

TD-36

TD-36 485

TR-36

TR-36B

Description

This command set and display Caller ID parameters and data.
The modem supports different standards of CID (Caller Identification) which is set with
the mode parameter. Which standard used varies between countries and operators,
please check with your operator for correct mode.
The format parameter sets the way of presenting the CID/A-number. When A-number
detection is enabled there will be no presentation, but the modem will compare the CID
to the numbers stored in the WACCTAB. On a true compare the modem will answer
the call immediately. If the CID not compares to a number in the WACCTAB the normal
answering procedure controlled by S0 and ATA takes place.

Syntax:

AT*WCID = <format>,<mode>

AT*WCID = ?

AT*WCID?

Parameters:

<format>

0

Disables Caller ID /A-Number

1 Formated

CID

2

Unformated CID

3

A-Number detection

<mode>

0

Between first and second ring

1

After detecting CAS

2

After line reversal

3

DTMF CID

Command example

Possible responses

Note

AT*WCID = 1,3

OK

Selects DTMF Caller ID
with formated string pres-
entation.

AT*WCID = 3,3

OK

Selects A-Number detec-
tion based on DTMF CID

AT*WCID?

*WCID: 1,3

Display current

OK

*WCID

settings

AT*WCID = ?

*WCID: (0-3), (0-3)

Display command

OK

parameters