Westermo TDW-33 User Manual

Page 41

Advertising
background image

6618-3202

41

*WCBTAB – Secure access table

Supported by:

TDW-33

TD-36

TD-36 485

TR-36

TR-36B

Description

The command handle numbers and password for secure callback, secure access, secure
connections etc. The command is used for the following services:

Secure Callback

Secure Access
The Secure Access Table consist of a table of 10 Secure Access Entries. Where a Secure
Access Entry consist of outgoing number field (size is up to 20 characters long), a pass-
word field (if used, size should be between 6 and 12 characters long, otherwise 0 size)

Syntax:

AT*WCBTAB = <entry>,<”num”>,<”psword”>

AT*WCBTAB=?

AT*WCBTAB?

Parameters:

<entry>
Secure callback entry [1-10].

<”num”>
Secure callback entry number [0-20 characters].

<”psword”>
Secure callback entry password [0, 6-12 characters].

Command example

Possible responses

Note

AT*WCBTAB = 1,

OK

Set number (12345) and

”12345”,”QWERTY”

password (“QWERTY”)
in entry 1

AT*WCBTAB=2,”678”,”” OK

Set number (678)
in entry 2.

AT*WCBTAB? OK

List

parameters

AT*WCBTAB = ?

*WCBTAB : (0-3),

(“0-20

CHAR”),

(“0,6-12

CHAR”)

OK

List command parameters

AT*WCBTAB=1, "", ""

OK

Delete entry

ERROR

Otherwise

S register: None

Advertising
This manual is related to the following products: