background image

6618-3202

62

Register

Function

Range

Units

Saved

Default

Note

S5

Backspace
Character

0–128

ASCII

*

8

S5 holds the ASCII value
of the back space control
character. The default value
is 8. The backspace char-
acter must not be set to
avalue corresponding to a
printable ASCII character
(which is between 33 and
126).

S6

Dial Delay
Blind dialing

0–255

s

*

3

This register programs
the pause time before
continuing the dial process.
(in case there is no wait-
ing for dialtone). Units is in
seconds. Maximum = 255.
Default = 3

S7 Wait

Time

for Carrier,
Silence, or
Dial Tone

0–255

s

*

50

This register gives the
answer tone and silence
timeout during dialing
before hanging up. Units is
in seconds. Maximum = 255.
Default = 50. In leased line
mode, this register is used
as synchronisation timeout
(answer tone – calling tone
synchronisation) between
the calling and answering
modem. If the timeout is
expired, the modem will
restart it's training until the
number of synchronization
attempts is reached.