Network requirements, Configuration procedure – H3C Technologies H3C SecPath F1000-E User Manual

Page 146

Advertising
background image

136

{

URL: http://192.168.0.111:8080/portal.

[SecPathA] portal server newpt ip 192.168.0.111 key portal port 50100 url

http://192.168.0.111:8080/portal

# Enable Layer 3 portal authentication on the interface connecting SecPath B.

[SecPathA] interface gigabitethernet 0/2

[SecPathA–GigabitEthernet0/2] portal server newpt method layer3

[SecPathA–GigabitEthernet0/2] quit

On SecPath B, configure a default route to subnet 192.168.0.0/24, setting the next hop as 20.20.20.1.
(Details not shown.)

Configuring direct portal authentication with extended
functions

Network requirements

As shown in

Figure 120

:

•

The host is directly connected to the SecPath and the SecPath is configured for direct portal
authentication. The host is assigned with a public network IP address either manually or through

DHCP. If a user fails security check after passing identity authentication, the user can access only

subnet 192.168.0.0/24. After the user passes security check, the user can access Internet resources.

•

A RADIUS server serves as the authentication/accounting server.

Figure 120 Network diagram

Configuration procedure

NOTE:
•

Configure IP addresses for the host, SecPath, and servers as shown in

Figure 120

and make sure that

routes are available between devices before extended portal is enabled.

•

Configure the RADIUS server properly to provide authentication/accounting functions for users.

1.

Configure a RADIUS scheme on the SecPath:
# Create a RADIUS scheme named rs1 and enter its view.

<SecPath> system-view

Advertising