Configuring a time range at the cli – H3C Technologies H3C SecPath F1000-E User Manual

Page 71

Advertising
background image

61

Figure 63 Time range resource configuration page

Table 19 Configuration items

Item Description

Name

Enter the name for the time range resource.

Periodic Time Range

Start Time

Set the start time of the periodic time range, in the
hh:mm format (24-hour clock).

End Time

Set the end time of the periodic time range, in the hh:mm
format (24-hour clock). The end time must be greater
than the start time.

Sun., Mon., Tues., Wed.,
Thurs., Fri., and Sat.

Select the day or days of the week on which the periodic
time range is valid.

Absolute Time Range

From

Set the start time of the absolute time range. The time of
the day is in the hh:mm format (24-hour clock), and the
date is in the MM/DD/YYYY format.

To

Set the end time of the absolute time range. The time of
the day is in the hh:mm format (24-hour clock), and the

date is in the MM/DD/YYYY format. The end time must

be greater than the start time.

Configuring a time range at the CLI

To configure a time range:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Configure a time range.

time-range time-range-name
{ start-time to end-time days [ from
time1 date1
] [ to time2 date2 ] |

from time1 date1 [ to time2 date2 ]

| to time2 date2 }

By default, no time range exists.
Repeat this command with the
same time range name to create

multiple statements for a time
range.