Switcher polling address, Switcher polling address -43 – Grass Valley Performer SD User Manual
Page 75
Advertising

2-43
Installation Reference
Switcher Polling Address
Performer will accept a polling address from 0 to 255. A
polling address is necessary if more than one switcher is being
controlled by a single controller. The full address range is not
available to all protocols. Refer to the list below to see which
addresses your protocol allows.
Performer ASCII
Full Range
TEN-XL ASCII
00-99 (2 BCD numbers. See
illustration.)
TEN-XL SMPTE
40-255 (28H-FFH)
GVG Model 100 or 110
Full Range
GVG Model 200
0-23
GVG Model 300
0-7
SMPTE 3245-E
40-255 (28H-FFH)
NOTE:
For addressing, refer to
the instructions for the control
panel you are using (page 2-54 f or Performer remote panel, or
page 2-75 for TEN –20, 20–TEN remote panels)