Programming: Special functions

11.2

Dynamic Collision Monitoring (software option)

11

340

TNC 640 | User's Manual for DIN/ISO Programming | 5/2013

Deactivating collision monitoring

If you have to reduce the distance between collision-monitored

objects for lack of space, the collision monitoring function can be

deactivated.

Danger of collision!

If you deactivate collision monitoring, the TNC does

not output an error message with a pending collision.

With inactive collision monitoring the symbol for

collision monitoring in the operating mode bar starts

to blink:

In addition, the TNC shows a corresponding symbol

in the position display (see the table below).

Symbols in the status display show the condition of collision

monitoring:

Function

Symbol

Collision monitoring active

Collision monitoring is not available

Collision monitoring is not active

Shift the soft-key row if necessary

Select the menu for deactivating collision

monitoring
Select the

Manual Operation menu item

To deactivate collision monitoring, press the ENT

key, and the symbol for collision monitoring in the

operating mode display starts to blink

Move axes manually, pay attention to traverse direction

To reactivate the collision monitor: Press the ENT key