First Steps with the TNC 640

1.4

Graphically testing the first part

1

56

TNC 640 | User's Manual for DIN/ISO Programming | 5/2013

1.4

Graphically testing the first part

Selecting the correct operating mode

You can test programs only in the Test Run mode:

Press the

Test Run operating mode key: the TNC

switches to that mode

Further information on this topic

Operating modes of the TNC: See "Modes of Operation",

page 71
Testing programs: See "Test Run", page 519

Selecting the tool table for the test run

You only need to execute this step if you have not activated a tool

table in the Test Run mode.

Press the PGM MGT key: The TNC opens the file

manager
Press the SELECT TYPE soft key: The TNC shows

a soft-key menu for selection of the file type to be

displayed
Press the SHOW ALL soft key: The TNC shows all

saved files in the right window
Move the highlight to the left onto the directories

Move the highlight to the

TNC:\ directory

Move the highlight to the right onto the files

Move the highlight to the file TOOL.T (active tool

table) and load with the ENT key: TOOL.T receives
the status

S and is therefore active for the test run

Press the END key: Exit the file manager

Further information on this topic

Tool management: See "Enter tool data into the table",

page 156
Testing programs: See "Test Run", page 519