Displaying a basic rotation, Canceling a basic rotation – HEIDENHAIN TNC 640 (34059x-02) ISO programming User Manual

Page 481

Advertising
background image

Compensating workpiece misalignment with 3-D touch probe

15.8

15

TNC 640 | User's Manual for DIN/ISO Programming | 5/2013

481

Displaying a basic rotation

When you select the PROBING ROT function, the TNC displays
the active angle of basic rotation in the dialog

Rotation angle. The

TNC also displays the rotation angle in the additional status display

(STATUS POS.).
In the status display a symbol is shown for a basic rotation

whenever the TNC is moving the axes according to a basic rotation.

Canceling a basic rotation

Select the probe function by pressing the PROBING ROT soft

key

Enter a rotation angle of zero and confirm with the SET BASIC

ROTATION soft key

Terminate the probe function by pressing the END soft key