Datum Setting with 3-D Touch Probe

15.9

15

TNC 640 | User's Manual for DIN/ISO Programming | 5/2013

487

Setting the datum in the intersection of multiple holes:

Preposition the touch probe approximately in the

center of the hole

Hole is to be probed automatically: Define by soft

key

To probe the workpiece, press the machine

START button. The touch probe probes the circle

automatically.

Repeat the probing procedure for the remaining

elements

Terminate the probing procedure and switch to the

evaluation menu: Press the EVALUATE soft key

Datum: In the menu window, enter both

coordinates of the circle center, confirm with the

SET DATUM soft key, or write the values to a table

(See "Writing measured values from the touch

probe cycles in a datum table", page 472, or See

"Writing measured values from the touch probe

cycles in the preset table", page 473)

Terminate the probing function: Press the END

soft key

Setting a center line as datum

Select the probe function: Press the PROBING

soft key

Position the touch probe at a position near the first

touch point

Select the probing direction by soft key

Start the probing procedure: Press the NC Start

button

Position the touch probe at a position near the

second touch point

Start the probing procedure: Press the NC Start

button

Datum: Enter the coordinate of the datum in the

menu window, confirm with the SET DATUM soft

key, or write the value to a table (See "Writing

measured values from the touch probe cycles in a

datum table", page 472, or See "Writing measured

values from the touch probe cycles in the preset

table", page 473.

Terminate the probing function: Press the END key