Installing the option, A1000 – Yaskawa SI-EP3 PROFINET Technical Manual User Manual

Page 14

Advertising
background image

5 Installation Procedure

14

YASKAWA ELECTRIC SIEP C730600 69A 1000-Series Option SI-EP3 Technical Manual

Installing the Option

Remove the front covers of the drive before installing the option. Refer to the drive instruction manual for directions on
removing the front covers. Cover removal varies depending on drive size. This option can be inserted only into the
CN5-A connector located on the drive control board.

Note: Refer to the instruction manual of a specific drive for information on removing and installing the operators and the covers.

DANGER! Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply could result in death

or serious injury. Before installing the option, disconnect all power to the drive and wait at least the amount of time specified on the

drive front cover safety label. After all indicators are off, measure the DC bus voltage to confirm safe level, and check for unsafe

voltages before servicing. The internal capacitor remains charged after the power supply is turned off.

1.

Shut off power to the drive, wait the appropriate amount of time for voltage to dissipate, then remove the digital
operator (D) and front covers (C, F). Front cover removal varies by drive model.

NOTICE: Damage to Equipment. Observe proper electrostatic discharge procedures (ESD) when handling the option, drive, and

circuit boards. Failure to comply may result in ESD damage to circuitry.

Figure 3

Figure 3 Remove the Front Covers and Digital Operator

2.

With the front covers and digital operator removed, apply the LED label (E) in the appropriate position on the
drive top front cover (C).

Figure 4

Figure 4 Apply the LED Label

C

D

F

A1000

NS

MS

C

E

A1000

PROFINET_E_conditional.book 14 ページ 2015年2月25日 水曜日 午後5時17分

Advertising