10 Troubleshooting

YASKAWA ELECTRIC

SIEP C730600 69A 1000-Series Option SI-EP3 Technical Manual

47

Minor Faults and Alarms

Digital Operator Display

Fault Name

oFA04

Option fault
Option flash write mode

Cause

Possible Solution

Option hardware fault

Replace the option

Digital Operator Display

Fault Name

to

oFA30 to oFA43

Option Fault (CN5-A)
Communication ID error.

Cause

Possible Solution

Option hardware fault.

Replace the option. Contact Yaskawa for assistance.

Digital Operator Display

Fault Name

oFb00

Non-Compatible Option connected to drive port CN5-B
Non-compatible option is connected.

Cause

Possible Solution

Non-compatible option connected to
drive port CN5-B.

Use only compatible options. Connect the SI-EP3 to CN5-A. For other option connections, refer to the
Installation Manual for those options.

Digital Operator Display

Fault Name

oFb02

Option Fault (CN5-B)
Two of the same option are connected simultaneously.

Cause

Possible Solution

Options AI-A3 or D1-A3 connected to
the CN5-B port while an option was
connected to CN5-A.

Only one of these options, AI-A3, DI-A3 or SI-



option can be connected to the drive at the same time.

The SI-N3 must be connected to CN5-A.

Digital Operator Display

Fault Name

oFC00

Non-Compatible Option connected to drive port CN5-C
Non-compatible option is connected.

Cause

Possible Solution

Non-compatible option connected to
drive port CN5-C.

Use only compatible options. Connect the SI-EP3 to CN5-A. For other option connections, refer to the
Installation Manual for those options.

Digital Operator Display

Fault Name

oFC02

Option Fault (CN5-C)
Two of the same options are connected simultaneously.

Cause

Possible Solution

Options AI-A3 or D1-A3 connected to
the CN5-C port while an option was
connected to CN5-A.

Only one of these options, AI-A3, DI-A3 or SI-



option can be connected to the drive at the same time.

The SI-N3 must be connected to CN5-A.

Digital Operator Display

Minor Fault Name

CALL

Serial Communication Transmission Error
Communication has not yet been established.

Cause

Possible Solution

Minor Fault

(H2- = 10)

Communication wiring or terminal resistor
connection is faulty. There is a short circuit, or
an option component is not connected
properly.

Check for wiring errors and correct the wiring.
Remove any ground shorts and reconnect loose wires.

Yes

Master-side programming error.

Check communications at start-up and correct programming errors.

Damaged communication circuitry.

Perform a self-diagnostics check and replace the drive if the fault