5 Installation Procedure

YASKAWA ELECTRIC

SIEP C730600 69A 1000-Series Option SI-EP3 Technical Manual

15

3.

Insert the option (B) into the CN5-A connector (M) located on the drive and fasten it using one of the included
screws (H).

Figure 5

Figure 5 Insert the Option

4.

Connect the ground wire (I) to the ground terminal (L) using one of the remaining provided screws (H). Connect
the other end of the ground wire (I) to the remaining ground terminal and installation hole on the option (B) using
the last remaining provided screw (H) and tighten both screws to 0.5 to 0.6 Nm (4.4 to 5.3 in lbs).

Figure 6

Figure 6 Connect the Ground Wire

Note: There are two screw holes on the drive for use as ground terminals (L). When connecting three options, two ground wires will

need to share the same drive ground terminal.

NS

MS

M

H

B

A1000

NS

MS

H

I

L

B

A1000

PROFINET_E_conditional.book 15 ページ 2015年2月25日 水曜日 午後5時17分