Parameter Data Transfer Examples

The following example shows how parameter data is transferred using the acyclic parameter access mechanism's READ
and WRITE.

Example 1: Reading a drive parameter

To read a Yaskawa Drive parameter, use the PNU of 1 and the actual address of the parameter in the SubIndex.

Write Request (Read Parameter Value)

Positive Read Response to Read Request

PROFIdrive Parameter Channel

Negative Response to PROFIdrive Read Request

0x78

PZD map failure

Parameter cannot be mapped to PZD (size mismatch or non-existent).

0x79

PZD memory failure

Parameter cannot be mapped to PZD (out of memory).

0x7A

Multiple PZD map

Parameter cannot be mapped to PZD (multiple PZD write).

0x8C

Set torque mode error

Cannot change mode to TORQUE (frequency is used).

0x90

Illegal Request ID

The request ID of the response is illegal.

Error #

Meaning

Used at

01 01 B0 2E 08 05 81 01 01 44 01 00 14

(44H = Error)