Control Power Input Terminals (L1C, L2C), External
Regenerative Resistor Terminals (B1, B2)

Model

Main Circuit Input Terminals

(L1C, L2C)

*1

External Regeneration

Resistor Terminals

(B1, B2)

Main
Circuit

Power
Supply

Capacity

(kW)

FSP-

Wire Type

& Size
(mm

2

)

Terminal

Screw

Size

Tightening

Torque

(N·m)

Wire Type

& Size
(mm

2

)

Terminal

Screw

Size

Tightening

Torque

(N·m)

0.03 A3B*
0.05 A5B*
0.10 01B*

Single-
phase

100V

0.20 02B*

HIV l.25

HIV1.25

0.03 A3A*
0.05 A5A*
0.10 01A*
0.20 02A*

Single-
phase

200V

0.40 04A*

HIV 1.25

HIV1.25

0.75 08A*

Single-

phase
220V

1.50 15A*

HIV 1.25

M4

1.2 to 1.4

HIV1.25

M4

1.2 to 1.4

2.00 20A*

HIV2.0

Three-

phase
200V

3.00 30A*

HIV 1.25

M4

1.2 to 1.4

HIV3.5

M4

1.2 to 1.4

0.50 05D*
1.00 10D*
1.50 15D*

2.00 20D*
3.00 30D*

HIV1.25

Three-
phase

400V

5.00 50D*

HIV 1.25

M4

1.2 to 1.4

HIV2.0

M4

1.2 to 1.4

*1. Terminal symbols +24 V and 0 V are for 3-phase 400V FSP Amplifiers only.