Wiring

5.5.2. Single-phase 200V 0.8kW and 1.5kW Main Circuit

Observe the following points.
1. Connect main power supply shown below to L1 and L3 terminals.

Power supply is single-phase, 220 to 230VAC +10% to -15%,

50/60Hz. If power supply of 187 V (-15% of 220V) or less is used,
alarm A.41 indicating voltage shortage, may occur when accelerating
to max speed with max torque of motor.

2. Short-circuit

B2 and B3 terminals using the internal regenerative

resistor. If capacity of the regenerative resistor is insufficient, remove

the lead between B2 and B3 terminals and connect an external
regenerative resistor unit to B1 and B2 terminals.

34

Personal Computer

Cable type P/N: YS-12

Host controller

FSP Amplifier is compatible with most

PLC motion controllers and indexers.

Used

for

a

servomotor

with

a

brake.

Advertising