Overload characteristics, Cable specifications, Recommended ferrite cores – Yaskawa FSP Short Form User Manual
Page 50: Shield box

FSP Amplifier Short Form Installation Guide
Peripheral Devices
50
9.3. Cable Specifications
Shield cables should be used for the following cables:
•
AC power input line cable (between power supply and noise filter)
•
Servomotor cable (between FSP Amplifier and servomotor)
•
Encoder cable (between FSP Amplifier and servomotor)
•
Controller cable (between FSP Amplifier and controller)
9.4. Recommended Ferrite Cores
Cable
Encoder Cable
Power Cable
Manufacturer Absolute
Serial 30W to 400W
0.8kW to 5kW
Tokin Corp.
ESD-SR-25
ESD-SR-25
ESD-SR-25
—
Fair-Rite Corp.
0444173551
0444164181
0444173551
—
TDK Corp.
—
—
—
PC40T96x20x70
9.5. Shield Box
A shield box, a closed metallic enclosure, should be used for shielding from
electromagnetic interference. The structure of the box should allow the main
body, door, cooling unit etc. to be attached to the ground. The box opening
should be as small as possible.