FSP Amplifier Short Form Installation Guide

Peripheral Devices

50

9.3. Cable Specifications

Shield cables should be used for the following cables:

AC power input line cable (between power supply and noise filter)

Servomotor cable (between FSP Amplifier and servomotor)

Encoder cable (between FSP Amplifier and servomotor)

Controller cable (between FSP Amplifier and controller)

9.4. Recommended Ferrite Cores

Cable

Encoder Cable

Power Cable

Manufacturer Absolute

Serial 30W to 400W

0.8kW to 5kW

Tokin Corp.

ESD-SR-25

ESD-SR-25

ESD-SR-25

Fair-Rite Corp.

0444173551

0444164181

0444173551

TDK Corp.

PC40T96x20x70

9.5. Shield Box

A shield box, a closed metallic enclosure, should be used for shielding from
electromagnetic interference. The structure of the box should allow the main

body, door, cooling unit etc. to be attached to the ground. The box opening
should be as small as possible.

Advertising