FSP Amplifier Short Form Installation Guide

Wiring

5.6. AC Power Source Supply

Use the FSP Amplifier AC power source supply according to product ratings.
See the following table for details.

Power

FSP

Amplifier

Motor

Output

S pecifications

Connection

Terminals

FSP-A3A* to

FSP-04A*

30, 50, 100,

200, and
400W

1-phase 200VAC to 230VAC
(+10% to -15%), 50/60 Hz

L1, L2 (Main)
LIC, L2C
(Control)

1-phase 220VAC to 230VAC

*1

(+10% to -15%), 50/60 Hz

38

L1, L3 (Main)

Single-

Phase
200V

FSP-08A* and
FSP-15A*

750 W and
1.5kW

1-phase 200VAC to 230VAC
(+10% to -15%), 50/60 Hz

L1C, L2C

(Control)

3-phase 220VAC to 230VAC
(+10% to -15%), 50/60 Hz

L1, L2, L3
(Main)

Three-
Phase

200V

FSP-10A* to
FSP-30A*

1.0, 2.0, and
3.0kW

1-phase 200VAC to 230VAC
(+10% to -15%), 50/60 Hz

L1C, L2C

(Control)

3-phase 380VAC to 480VAC
(+10% to -15%), 50/60 Hz

L1, L2, L3

(Main)

Three-

Phase
400V

FSP-05D* to

FSP-50D*

0.5, 1.0, 1.5,

2.0, 3.0 and
5.0kW

DC power supply +24V (

±15%)

(not provided by YET)

24 V, 0 V
(Control)

*1. When a power supply of 187V (-15% of 220V) or less is used, alarm A.41, indicating voltage shortage,
may occur when accelerating to max speed with max torque of servomotor.

5.7. DC Power Source Supply

3-Phase 400V FSP Amplifier models require 24VDC for its control circuit. The
user must provide a 24VDC ± 15% power supply with a current capacity of at
least 1 Amp. This power supply must also be able to withstand a surge of up to
3A for 50ms. It should be connected to the terminals marked 24V and 0V on the
FSP Amplifier.

WARNING

Do not connect AC voltage to these terminals.

Doing so may cause permanent damage to the amplifier.

5.8. Noise Control

• If the signal line is affected by noise, malfunction may result.
• Separate power cables from control cables.
• Make the signal line as short as possible and use twisted-pair wires.

• Never use a line filter (for power input) for servomotor circuit. If

peripheral devices malfunction due to the noise from the FSP Amplifier,
insert a line filter (for output, type LF-310KA, made by Tokin Corp.)

between the servomotor and the FSP Amplifier.