FSP Amplifier Short Form Installation Guide

Inspection and Maintenance

7. Inspection and Maintenance

This section describes the basic inspection and maintenance procedures for the FSP
Amplifier and battery replacement for absolute encoder. If any failure occurs on the
FSP Amplifier, refer to the Sigma FSP Servo System User’s M anual (Document #

YEA-SIA-FSP-3), Troubleshooting.

Contact your YEA representative if the problem persists.

WARNING

Be sure to turn OFF power before inspection or maintenance.

Failure to observe this warning could result in electric shock.

Never open the terminal cover while power is ON, and never turn ON

power when the terminal cover is open.

Failure to observe this warning could result in electric shock.

After turning OFF power, wait at least five minutes before servicing

the product.

Otherwise, residual electric charges could result in electric shock.

CAUTION

Never change wiring while power is ON.

Failure to observe this caution could result in electric shock or personal injury.

7.1. FSP Amplifier Inspection

The inspection and maintenance procedures listed in the table below should be
performed at least once every year.

Item Frequency

Procedure

Remedy

Clean unit interior
and circuit boards

At least once
per year

Check for dust, dirt and oil on
surfaces.

Clean with
compressed air if

necessary.

Loose screws

At least once
per year

Check for loose terminal block
and connector screws.

Tighten any loose
screws.

Defective parts in

unit or on circuit
boards

At least once

per year

Check for discoloration or

damage due to heating.

Contact your YEA

representative.