F6-41
(3D6)

Baud Rate

CompoNet communication speed
0: 93.75 kbps
1: Detect automatically
2: 1.5 Mbps
3: 3 Mbps
4: 4 Mbps
5 to 255: Unused
Note: Used in the CompoNet Link Object

Default: 1
Range: 0 to 4

F6-52

(3C3)

<4>

PCA setting

I/O Polled Consuming Assembly data instance
Note: Used in the Connection Object

Default: 21
Min: 0
Max: 255

F6-53

(3C4)

<4>

PPA setting

I/O Polled Producing Assembly data instance
Note: Used in the Connection Object

Default: 71
Min: 0
Max: 255

F6-56
(3D7)

Speed Scaling

Sets the scaling factor for the Speed Monitor in the
CompoNet Object Class 2A hex
Note: Used in the AC/DC Drive Object

Default: 0
Min: -15
Max: 15

F6-57
(3D8)

Current Scaling

Sets the scaling factor for the Output Current Monitor in
the CompoNet Object Class 2A hex
Note: Used in the AC/DC Drive Object

Default: 0
Min: -15
Max: 15

F6-58
(3D9)

Torque Scaling

Sets the scaling factor for the Torque Monitor in the
CompoNet Object Class 2A hex
Note: Used in the AC/DC Drive Object

Default: 0
Min: -15
Max: 15

F6-59

(3DA)

Power Scaling

Sets the scaling factor for the Power Monitor in the
CompoNet Object Class 2A hex
Note: Used in the AC/DC Drive Object

Default: 0
Min: -15
Max: 15

F6-60

(3DB)

Voltage Scaling

Sets the scaling factor for the Voltage Monitor in the
CompoNet Object Class 2A
Note: Used in the AC/DC Drive Object

Default: 0
Min: -15
Max: 15

F6-61

(3DC)

Time Scaling

Sets the scaling factor for the Time Monitor in the
CompoNet Object Class 2A hex
Note: Used in the AC/DC Drive Object

Default: 0
Min: -15
Max: 15

U6-80

(7B0)

MAC ID from
Network

Actual MAC address
Note: Used in the CompoNet Link Object

Min: 0
Max: 63

U6-81

(7B1)

Baud Rate from
Network

CompoNet actual communication speed
0: 93.75 kbps
2: 1.5 Mbps
3: 3 Mbps
4: 4 Mbps
Note: Used in the CompoNet Link Object

Default: 0
Range: 0 to 4

U6-82 ~

U6-99

Not Used

No.

(Addr. Hex)

Name

Description

Values