6 Procedure A

YASKAWA SIEP YEACOM 06A V1000 Option PROFINET SI-EP3/V Technical Manual

17

3.

IP20/Open-Chassis models CIMR-VAB.
Remove the bottom cover of the drive. Apply pressure using fingers to the tabs on each side of the bottom cover.
Pull the bottom cover away from the drive while pushing in on the tabs to release the cover from the drive. Refer
to

Figure 8

for details.

Refer to

Figure 9

for drive models CIMR-VBA0006B to BA0018B, 2A0010B to 2A0069B, and 4A0001B to

4A0038B, which require removing the terminal cover prior to removing the bottom cover.

Figure 8

Figure 8 Remove the Bottom Cover on an IP20/Open-Chassis Drive

(Models CIMR-VBA0001B to BA0003B and 2A0001B to 2A0006B)

Figure 9

Figure 9 Remove the Terminal Cover and Bottom Cover on an IP20/Open-Chassis Drive

(Models CIMR-VBA0006B to BA0018B; 2A0010B to 2A0069B; 4A0001B to 4A0038B)

4.

Select one of the four different length ground wires packaged with the option.
Choose the proper ground wire by first removing the ground terminal screw from the drive,

Figure 11

. Test fit the

screw (size M3.5 to M6) into each of the four ground drive-side ring lugs prior to installation. Ground wire
selection varies by drive model.

Figure 10

Figure 10 Ground Wire Selection

To Option ground screw FE
Screw size: M3

To drive ground terminal
Screw size: M3.5 to M6