6 Procedure A

18

YASKAWA SIEP YEACOM 06A V1000 Option PROFINET SI-EP3/V Technical Manual

5.

On IP20/Open-Chassis models, connect the drive side of the ground wire to the drive ground terminal.

Figure 11

Figure 11 Ground Wire Connection on IP20/Open-Chassis

6.

Proceed to STEP

12.

on page

20

to continue the option installation procedure for IP20/Open-Chassis models.

7.

From STEP

2.

for IP20/NEMA Type 1 enclosure models CIMR-VAF, loosen the screw on the front of

the NEMA Type 1 terminal cover and remove it from the drive. Refer to

Figure 12

for details.

Refer to

Figure 13

for drive models CIMR-VBA0006F to BA0018F, 2A0010F to 2A0069F, and 4A0001F to

4A0038F, which require removing the plastic terminal cover prior to removing the NEMA Type 1 terminal cover.

Figure 12

Figure 12 Remove the NEMA Type 1 Terminal Cover

Figure 13

Figure 13 Remove the Terminal Cover on an IP20/NEMA Type 1 Drive

(Models CIMR-VBA0006F to BA0018F; 2A0010F to 2A0069F; 4A0001F to 4A0038F)

Ground terminal

Ground wire

Ground wire

Drive-side
ground terminal
ring lug (size varies):
M3.5 to M6

Ring lug for
Option ground FE
Size: M3