User Manual for ACIS Version

Uncontrolled when printed

© RISCO Group

38



Figure 26: Configuration of Basic Devices



2. In the Basic tab, enter the following in the fields.



Table 7: Configuration of Basic Devices

Field Name

Description

Sequence Number

This is the Door Sequence Number.

Door Name

The Door Name appears by default when you select a Door from the tree view.
You may change the door name as per your requirement.

Strike Delay

It is the time for which the door strike stays on when access is granted. If the door
does not open before the end of the door strike delay, it shall generate an event
declaring that the card was presented but the door was not opened if the user
has chosen to generate this event.

Enter the time in seconds. Default is 10 seconds

Reopening of the relay

Select one of the options as mentioned below:

• At the End of Strike Delay
• As Soon As Door Closes
• As Soon As Door Opens.