8.4. OSD Timeout
Use OSD Timeout to set the amount of time the menu screens and control bars are visible,
without making any changes, before they timeout and close automatically.
There are three increments: 6 Seconds, 15 Seconds, and 30 Seconds.
From the Technician Menu, press – to select OSD Timeout and then press Menu.
Use + and – to select a time increment and press Menu.
Select Back and Exit to exit the OSD.
8.5. Splash Screen
Use this option to turn a splash screen on or off. The splash screen appears for approximately
eight seconds when 28V power is first applied to the display.
When enabled, the Rosen Aviation splash screen appears. When disabled, the screen remains
black.
Highlight TechnicianSplash Screen and press Menu.
Use + and – to set the option and then press Menu.
Select Back and Exit to exit the OSD.
8.6. Front Panel LED
(Available on select models)
The Front Panel LED option turns the power LED on or off. When
the option is Off, the power LED will be black.
Figure 32 Front touch pad with LED indicator
When it is On, the power LED will have the following states:
Green
indicates the display is receiving power.
Amber
indicates the display is in standby mode.
Red
indicates the display is registering an error.
Black
indicates the display is receiving no power.
Highlight TechnicianFront Panel LED and press Menu.
Use + and – to set the option and then press Menu.
Press Exit to exit the OSD.