Rosen Aviation 9000 Series : 9 inch High Definition SlimLine User Manual
Page 29
![background image](/files/859319/content/doc029.png)
Rosen Aviation
Personal Displays
Document Number: 104461
Revision: F
Date: 03/13/14
Template: 4.4.1.6FM2; Revision A; 12/06/12
Page 29 of 32
Description
Section
Category
Comments
Power Input
16
Normal Operating Conditions (DC)
16.6.1
Average Value Voltage (DC)
16.6.1.1
Z
Ripple Voltage (DC)
16.6.1.2
Z
Momentary Power Interruptions (DC)
16.6.1.3
Z (A)
Seamless operation
through 200 msec, EUT
must self-recover for
interruptions longer than
200 msec.
Normal Surge Voltage (DC)
16.6.1.4
Z
Engine Starting Under Voltage Operation
(DC)
16.6.1.5
Z
Abnormal Operating Conditions
16.6.2
Voltage Steady State (DC)
16.6.2.1
Z
Momentary Under Voltage (DC)
16.6.2.3
Z
Abnormal Surge Voltage (DC)
16.6.2.4
Z
Voltage Spike
17
Voltage Spike
17.4
A
Audio Frequency Conducted
Susceptibility
18
AF Conducted Susceptibility- Power
Inputs
18.3.1
Z
Induced Signal Susceptibility
19
Magnetic Fields Induced Into Equipment
19.3.1
AC
Magnetic Fields Induced Into
Interconnecting Cables
19.3.2
AC
Electric Fields Induced Into
Interconnecting Cables
19.3.3
AC
Spikes Induced Into Interconnecting
Cables
19.3.4
AC
Radio Frequency Susceptibility
20
Conducted Susceptibility (CS) – 10 kHz to
400 MHz
20.4
T
Radiated Susceptibility (RS) – 100 MHz to
18 GHz
20.5
T