PLANET WGSW-2620HP User Manual
Page 140

User’s Manual of WGSW-2620HP
PD Classifications
A PD may be classified by the PSE based on the classification information provided by the PD. The intent of PD
classification is to provide information about the maximum power required by the PD during operation. Class 0 is the default
for PDs. However, to improve power management at the PSE, the PD may opt to provide a signature for Class 1 to 3.
The PD is classified based on power. The classification of the PD is the maximum power that the PD will draw across all
input voltages and operational modes.
A PD shall return Class 0 to 3 in accordance with the maximum power draw as specified by
Table 4-16-1.
Class
Usage
Range of maximum power used by the PD
0
Default
0.44 to 12.95 Watts
1
Optional
0.44 to 3.84 Watts
2
Optional
3.84 to 6.49 Watts
3
Optional
6.49 to 12.95 Watts
*4
Optional
12.95 to 25.50 Watts
Table 4-16-1:
Device class
Class 4 is defined for IEEE 802.3at high power used.
140