PLANET BSP-300 User Manual

Page 12

Advertising
background image

                                                           

 

User’s Manual of BSP-300

 

 

 

11

Max. solar array Voc 

60VDC 

Max. operating voltage   

45VDC 

Total current consumption 

While operating ‐32mA 

At idle ‐11mA 

High temperature shutdown 

100 Degree C disconnect solar and load 

80 Degree C reconnect solar and load 

Overload Capacity 

Over 15 Amp will cut off output load 

Battery Charging Characteristics 

Charge algorithm 

Bulk  charge  (constant  current),  Absorption  charge  (constant 
voltage) and Floating charge. Absorption and Floating charge with 

PWM protection. 

Maximum output current 

15A 

Nickel‐cadmium battery 

±  40  mV/Degree  Celsius  for  NiCad  type  batteries,  Charge  cut‐off 

@ 55 Degree C 

(Temperature compensation Baseline@ 25 Degree C) 

Lead‐acid battery 

(Default Setting)

±  60  mV/Degree  Celsius for  lead  acid  type  batteries,  Charge 

cut‐off @ 55 Degree C 

(Temperature compensation Baseline@ 25 Degree C) 

Float charge voltage 

DC 27.2V ( 26.0~30.0V ) 

Absorption charge voltage 

DC 29.2V ( 28.0~32.0V ) 

LVD 

(Low Voltage Disconnection) 

DC 22.2V ( 21.0~25.0V ) 

LVR 

(Low Voltage Reconnection) 

DC 24.8V ( 23.0~27.0V ) 

Standards Conformance 

Computer Interface 

IEEE 802.3 10Base‐T 

IEEE 802.3u 10/100Base‐TX 

IEEE 802.3ab 10/100/1000Base‐T 
IEEE 802.3at / 802.3af for PoE (Power over Ethernet) devices 

Regulation Compliance 

CE, FCC   