Toolbar on the top:

Item

Action

Open

Open the existing controller parameter file in the computer.

Save

Convert the controller parameters into a file and store it in the personal
computer.

Link PC

Set the serial port of the computer to connect to the controller.

Note:

1. Use the “automatic detection” function or manually select the

required serial port and then click “OK” to confirm the setting

2. If the connection between the controller and the computer has

failed, the user is not able to read or change the parameter
settings in the controller.

Default

Restore the parameter settings to the factory default.

Help

Message for the software version.

Last Set

Restore the current parameter settings in the utility to the previously
used parameter values.

New Set

Load the current parameter settings in the utility into the controller.

Exit

Exit the utility.

NOTE:

Always click on New Set button whenever there is a new change to the new setting.

Description of the Related Setting Items:

Low Voltage Disconnection and Low Voltage Reconnection:

When the battery voltage is lower

than the value for the low­voltage disconnection (LVD), the controller will stop supplying power to

 