Ge 66) – ProSoft Technology MVI69-EGD User Manual

Page 66

Advertising
background image

MVI69-EGD ♦ CompactLogix or MicroLogix Platform

Reference

GE Ethernet Global Data Communication Module

Page 66 of 96

ProSoft Technology, Inc.

November 3, 2008

Capabilities PDUs

PDU Type = 9

Capabilities Request

The capabilities request PDU command permits an application program to
request the supported capabilities of the EGD implementation on the destination
node. A capabilities request sent from a requesting node must be followed by a
capabilities response message from the responding node.

Packet
Info

Description Data

Source Port:

7937 (0x 1F01)

Destination Port:

7937 (0x 1F01)

Length:

xx bytes (0x 00 XX)

Checksum:

xxxxx (0x XX XX)

EGD's PDU Field:

Offset

Bytes

Hex code

PDU Type:

0

1

0x 09

Message Flag:

1

1

0x HH

Request ID:

2

2

0x HH HH

PVN1:

4

1

0x 01

Reserved:

5

1

0x HH

UDP

EGD:

Message Length:

6

2

0x HH HH

PDU Type = 10

Capabilities Response.

The capabilities response command PDU is sent in response a capabilities
request. This message returns the functional capabilities and limits of the
supported EGD implementation on the responding controller.

Packet
Info

Description Data

Source Port:

7937 (0x 1F01)

Destination Port:

7937 (0x 1F01)

Length:

xx bytes (0x 00 XX)

Checksum:

xxxxx (0x XX XX)

EGD's PDU Field:

Offset

Bytes

Hex code

PDU Type:

0

1

0x 0A

Message Flag:

1

1

0x HH

Request ID:

2

2

0x HH HH

PVN1:

4

1

0x 01

Status:

5

1

0x HH

Message Length:

6

2

0x HH HH

UDP

EGD:

Producer ID:

8

4

0x HH HH HH HH

Advertising