Read PDUs

PDU Type = 32

Read Request

The read request PDU is used to request the contents of one or more contiguous
groups of memory from a specific peer controller. The header defines parameters
which apply to the all of the individual cell references in the message. Each cell
reference specifies an offset into the specified Exchange or target-specific
address and the number of bytes to read. Based on the address type, the
Domain ID must contain an Exchange and Producer ID or target-specific address
which is valid on the destination node. A read request sent from a requesting
node must be followed by a read response message from the responding node.

Packet
Info

Description Data

Source Port:

7937 (0x 1F01)

Destination Port:

7937 (0x 1F01)

Length:

xx bytes (0x 00 XX)

Checksum:

xxxxx (0x XX XX)

EGD's PDU Field:

Offset

Bytes

Hex code

PDU Type:

0

1

0x 20

Message Flag:

1

1

0x HH

Request ID:

2

2

0x HH HH

PVN1:

4

1

0x 01

Option Length:

5

1

0x HH

Message Length:

6

2

0x HH HH

Configuration Signature:

8

2

0x HH HH

Address Type:

10

1

0x HH

Cell Count:

11

1

0x HH

Producer ID:

12

4

0x HH HH HH HH

Exchange ID:

16

4

0x HH HH HH HH

Time Stamp:

20

8

0x HH . . . HH

Reserved:

28

4

0x HH HH HH HH

The following two items are referred to as the exchange Cell. Each Cell
targets one [EGD Exchange] command line present in the EGD Module's
configuration file.

Offset: reads the DB Register specified in the Command.

Length: is Bytes count not Words.

Multiple Cells may be requested dependent on the Cell Count: field
specified above.

Offset:

32

2

0x HH HH