background image

AN-X-DCSNet2 Page

33

,ConnStats15

Sample File – DCS Master

The following sample file shows how data is mapped for an AN-X
configured as a DCS master.

ClxName,DCSmaster

ClxPrefix,DCSmaster2

ClxSlot, 0

DataOutput

,0,32,8

,1,32,32

,2,32,32

DataInput

,1,0,32

,2,0,32

ClxSlot, 15

DataOutput

DataInput

,0,0,32

,ConnStats0

,ConnStats15

Sending the Configuration to AN-X

When the configuration is complete, save it to a file. If you are using a
spreadsheet to create the configuration, save it as a file of type comma
separated variable (CSV).

To send the configuration to the AN-X:

1. Start your web browser

2. Enter the AN-X IP address as the address, for example, 192.168.0.10

3. Select Automation Network/Configure ControlLogix Support

4. Browse or type in the configuration file name

5. Click Send To AN-X

The web interface displays the result of the upload, either success or an
error message. To see further details, select Log Files/ControlLogix Log
(see page 54) and check for error messages.