Calibrations

C4705-90000

Adjustments

There are no electrical or mechanical adjustments required on DesignJet 700, 750C, 750C Plus

plotters and DesignJet 755CM printers.

Calibrations

The plotters/printers have several calibration procedures that must be performed under

certain conditions. Refer to the table below to determine when calibrations are required.

When Required

Calibration

When Required

Drop Detect

Line Sensor

Accuracy

Carriage is replaced or disassembled

Yes

Yes

Yes

Cartridge checking constantly rejects pens

Yes

No

No

Drive roller assembly is replaced

Yes

No

Yes

EdgeĆdetect failures occur

No

Yes

No

EEROM is cleared (Calibrations to be done

in this order)

Yes

Yes

Yes

Length of lines drawn by the plotter is not

as specified by the software

No

Yes

No

Main PCA is replaced without restoringthe

EEROM values

Yes

Yes

Yes

Mark Encoder is replaced

No

No

Yes

Media is not detected by the line sensor

No

Yes

No

Plots have consistent bandingdue to paper

advance error

No

No

Yes

Service ConfigPlot XĆmark distance is not

500mm ("1mm.); mono on inkjet film

No

No

Yes

Service station is replaced or disassembled

Yes

No

Yes

XĆaxis motor/encoder is replaced

No

No

Yes