Troubleshooting

C4705-90000

8-37

17. Drop Detector

The purpose of this test is to:

D Checkthe test signal.
D Checkif the drop detector is sensing ghost drops due to noise interference.
D Verify that the drop detector senses correctly.

The drop detector test performs these two tests:

D Blocked sensor test.
D Open sensor test.

Perform the drop detector test as follows:

1 In the Service Tests submenu, scroll to 17 Drop detector " and press Enter.

SERVICE TESTS

17 Drop detector

2 If the Drop DT Status: Good / Press Enter" message is displayed on the frontĆpanel,

then press Enter and go to step 4 to continue with the test.

3 If the Drop DT Status: Bad / Press Enter" message is displayed on the frontĆpanel, then

go to step 16 to troubleshoot the problem. Press Enter if you want to continue with the

test.

4 The Blocked Sensor Test / Open Sensor Test" message is displayed on the frontĆpanel.

5 Press the Up Arrow to perform the blocked sensor test.

If you want to perform the open sensor test, then go to step 10.

6 The Press Enter then Blocksensor" message is displayed on the frontĆpanel and

carriage moves to the right side of the plotter. Press Enter.

7 When the BlockSensor Now!!" message is displayed on the frontĆpanel, blockthe drop

detect sensor, which is located in the service station.

8 If the test passes, the Sensor Good / Press Enter" message is displayed on the

frontĆpanel.

9 If the test fails, the Sensor Bad / Press Enter" message is displayed on the frontĆpanel.

Go to step 16 to troubleshoot the problem.

The test is continued on the next page.