9. TTOE

The purpose of this test is to calibrate the Thermal TurnĆOn Energy for each cartridge.
Perform the TTOE test as follows:

1 In the Service Tests submenu, scroll to 9 TTOE" and press Enter.

SERVICE TESTS

9 TTOE

2 The Setting Voltages..." message is displayed on the frontĆpanel.

3 The plotter will automatically calibrate the black cartridge.

The Select a Position" message is displayed on the frontĆpanel. Use the Arrow buttons

toselect the cartridge that needs tobe tested.

4 Press the Enter button.
5 The Calibrating xxxx Pen" message is displayed on the frontĆpanel while the plotter

calibrates the cartridge.

xxxx represents the color of the cartridge that is being calibrated.

6 When the plotter has finished calibrating the cartridge, the TTOE Voltage #.## / Press

Enter" message is displayed on the frontĆpanel.

If the message

TTOE fail" is displayed on the front-panel, then the cartridge has failed the test.

To resolve the problem, try one of the following:

1 Clean the interconnect pad in the carriage or the cartridge that failed the test.
2 Replace the cartridge that failed the test.
3 Perform the pen continuity test ' page 8Ć30.
4 Replace the carriage ' page 6Ć34.

7 The Pen Voltage #.## / Press Enter" message is displayed on the frontĆpanel.

The pen voltage value (#.##) is for reference purposes only.