Service tests – HP 750 User Manual

Page 135

Advertising
background image

Troubleshooting

C4705-90000

8-17

Service Tests

The following is a list of all internal service tests available in the plotters. Instructions for

entering the service tests menu are given on page 8Ć20.

1 EEROM ' page 8Ć21

The purpose ofthis test is to clear or test the EEROM.

2 EEROM Clear Counters ' page 8Ć22

The purpose ofthis test is to reset the counters ofthe EEROM after periodic preventive

maintenance has been performed.

3 EEROM Model Type ' page 8Ć23

The purpose ofthis test is to set the correct plotter model (not applicable to the DesignJet

700). This test also allows you to view (get) which plotter model is currently set.

4 MIO ' page 8Ć24

The purpose ofthis test is to check ifthe MIO card is present and verify its functionality.

5 Main PCA ' page 8Ć25

The purpose ofthis test is to do an extended functionality check ofthe internal circuits of

the main PCA which are not involved with any other board.

6 MainĆCarriage Com ' page 8Ć26

The purpose ofthis test is to check all circuits involved in communicating between the

main PCA and the carriage.

7 Carriage ' page 8Ć27

The purpose ofthis test is to check the internal circuits ofthe carriage PCA.

8 Thermal Control ' page 8Ć28

The purpose of this test is to verify the functionality of the sense resistors and any

associated electronics.

9 TTOE ' page 8Ć29

The purpose ofthis test is to calibrate the Thermal TurnĆOn Energy for each cartridge.

10 Pen Continuity ' page 8Ć30

The purpose ofthis test is to check for proper interconnection between the cartridge(s)

and the carriage.

11 Pen ID ' page 8Ć31

The purpose ofthis test is to check the pen ID and the resistance values.

Advertising