HP 750 User Manual

Page 62

Advertising
background image

Do not force the frontĆpanel PCA cable out of its clamp. First pull the

clamp gently towards you to release the cable; then pull the cable easily

out of the clamp.

4 Disconnect all cable connectors from the main PCA.

C F U T I O N

Reassembling: Make sure you connect all cables in the correct orientation and in the correct

sockets.

5 Remove the eight screws that secure the

main PCA to the electronics enclosure.

Reassembling: Temporarily leave the screws

loose; tighten the serial and parallel connector

screws first; then tighten the PCA screws.

6 Lift the main PCA clear of the plotter.

Front-panel PCA

X-Encoder

(Media encoder)

Hung LE (P1)

Hung LE (P2)

Pinch-wheel
sensor

Media sensor

Primer sensor

Drop detector

Wiper stepper

Y – Carriage

motor

X – Media motor

Bail stepper

P18

Primer stepper

Bitronics

RS-232-C

SIMM’s

connectors

RAM

RAM

POST

CODE

M-10

Power supply

Tx 10

Calibrations: After installinga new

main PCA, if the EEROM data has not

been saved and loaded (see 6Ć9 note),

then the followingcalibrations must be

performed in the order listed:

1. DropĆdetector calibration ' page 7Ć4.

2. LineĆsensor calibration ' page 7Ć5.

3. Accuracy calibration ' page 7Ć6.

6-10

Removal and Replacement

C4705-90000