HP 750 User Manual

Page 151

Advertising
background image

Troubleshooting

C4705-90000

8-33

13. Mono PQ Plot

The purpose of this test is to check the print quality in monochrome at 600 dpi.
Perform the mono PQ plot test as follows:

Load media before performing this test.

1 In the Service Tests submenu, scroll to 13 Mono PQ Plot" and press Enter.

SERVICE TESTS

13 Mono PQ plot

2 The Unidirectional / Bidirectional" message is displayed on the frontĆpanel.

3 Press the Up Arrow to produce the mono PQ plot in a unidirectional mode or press the

Down Arrow to produce the mono PQ plot in a bidirectional mode.

4 The Printing PRESS ENTER when finished" message is displayed on the frontĆpanel

while the plotter produces the mono PQ plot.

5 Press the Enter button when the test has been completed.
6 For more information on troubleshooting the mono PQ plot ' page 9Ć13.

Advertising