“REC”: The signal is output during recording.

“PLAY”: The signal is output during playback.

“POWER”: The signal is output when the unit’s power
switch is on.

“REMAIN”: The signal is output when the remaining stor-
age capacity of main HDD, archive device reaches the
rate which is set in CAPACITY REMAIN.

5. Turn the SHUTTLE ring to the left or press the SET UP button.

Capacity remain setting

When MODE OUT is set to “REMAIN” and the remaining stor-
age capacity of main HDD or archive device is running out,
this unit gives a warning. The following shows how to set the
device and its remaining capacity ratio to give warning.

When the remaining storage capacity reaches

the assigned % remain during recording:
• The display of the recorded storage capacity
flashes when “DISPLAY MODE 3” is selected.
• The buzzer sounds when BUZZER in the <REAR
TERMINAL> menu is set to “REMAIN”.

Example: Setting CAPACITY REMAIN to “HDD-50%” (the
default setting is “HDD-10%”).

1. Display the <MENU SETTING> menu and turn the JOG
dial until the cursor is next to “REAR TERMINAL”.

DATA CLEAR SELECTION

COMMUNICATION SETTING

@REAR TERMINAL

SERVICE

2. Turn the SHUTTLE ring to the right to show the <REAR
TERMINAL> menu.

3. Turn the JOG dial until the cursor is next to “CAPACITY
REMAIN” and turn the SHUTTLE ring to flash the sub-item.

• The sub-item of the device will start flashing first. Choose
the device you want to set by using the JOG dial and SHUTTLE
ring. Then sub-item of the remain will start flashing.

<REAR TERMINAL>

MODE OUT PLAY

@

CAPACITY REMAIN HDD-10

%

4. Turn the SHUTTLE ring and JOG dial to show “HDD-50%”
and turn the SHUTTLE ring to the right to complete setting.

By turning the JOG dial, the sub-

item of CAPACITY REMAIN shown on the menu will
be changed as follows:

HDD ARC NONE

By turning the JOG dial, the sub-

item of CAPACITY REMAIN shown on the menu will
be changed as follows:

8% 6% 4% 2% 50%

10% 15% 20% 30% 40%

5. Turn the SHUTTLE ring to the left or press the SET UP
button.

CALL OUT setting

With this setting, the signal from CALL OUT terminal is emit-
ted externally to indicate a warning. The signal is emitted from
the CALL OUT terminal when the remaining storage capacity
reaches the preset amount. Likewise, the remaining storage
capacity of archive medium can be set. The CALL OUT signal
is also emitted when HDD FULL in the <INITIAL SET UP>
menu is set to “STOP”. In addition, while the CALL OUT sig-
nal is not included in these settings, there is a setting for CALL
OUT output when a problem occurs.

INFORMATION

For more on the relation between

Warning Display and CALL OUT terminal, please refer
to page 84. When the emission parameter in CALL
OUT is set to “Fixed”, the warning display will appear
unconditionally; when the parameter is set to
“Selectable”, the unit can be made to emit a CALL OUT
signal through additional settings. For example, when
the BUZZER setting on the <REAR TERMINAL> menu
is set to “WRNG”, the unit will sound a buzzer when
the remaining amount on the hard disk has reached
the figure specified on the <CALL OUT> menu.

Example: Setting CALL OUT of main HDD to “10%” (the
default setting is “FULL”) and CALL OUT of archive me-
dium to “20%” (the default is “NONE”).

1. Press the SET UP button to display the <MENU SETTING>
menu.

2.Turn the JOG dial to move the cursor to REAR TERMINAL
then turn the SHUTTLE ring to the right.

• The <REAR TERMINAL> menu will appear.

<REAR TERMINAL>
@MODE OUT REMAIN

CAPACITY REMAIN HDD-10

%


CALL OUT

3. Turn the JOG dial until the cursor is next to “CALL OUT”
and turn the SHUTTLE ring to the right to show the <CALL
OUT> menu.

<CALL OUT>
@HDD(ID:0~3) FULL
ARCHIVE(ID:4) NONE

4. Confirm that the cursor is next to “HDD” and turn the
SHUTTLE ring to the right to flash the sub-item.

<CALL OUT>
@HDD(ID:0~3) FULL

ARCHIVE(ID:4) NONE

5. Turn the JOG dial to flash “10%” and turn the SHUTTLE
ring to the right to complete setting.

<CALL OUT>
@HDD(ID:0~3) 10

%

ARCHIVE(ID:4) NONE

By turning the JOG dial, the item

of CALL OUT shown on the screen switches as
shown below:

FULL 2% 4% 6% 8% 10%

NONE 50% 40% 30% 20% 15%

“NONE”: No signal is emitted from the CALL OUT
terminal.