62

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Restrictions during Backup Recording

1. Selectable recording intervals for simultaneous backup

Recording interval for simultaneous backup of recorded
data is determined by the data-writing speed of the con-
nected device. For reference, the following chart provides
a list of interval modes which can be selected when the
unit is used in conjunction with a Hewlett-Packard C1556A
drive (DDS3). (The same modes apply when the main hard
disk drive has been expanded.)

SUPERIOR

HIGH

MEDIUM

STANDARD

BASIC

Non-
selectable

25F

12.5F

8.33F

6.25F

:Simultaneous backup is possible

IMAGE QUALITY

Field/sec.

2. Precautions when designating Timer simultaneous
backup

The Backup Program, which can be designated as an indi-
vidual operation, can also be designated with the RECORD
and POWER Programs. The following items apply when
designating these multiple program modes.

1) There may be restrictions imposed by the other record-
ing devices, it is recommended that adequate program
checks are run before actual operation.

*) Precautions when connecting devices requiring time to
halt startup (e.g., archive devices, tape recording devices
etc.)

• Using the Backup setting’s designated time plus 5 min-
utes (the halt startup time of the peripheral recording de-
vices) as a gauge, set the unit so that modes do not change.
(Refer to illustration 1.)

• Even when only designating the backup mode, add one
minute or more to the backup operation time, and set other
programs to start and stop. ( Refer to Illustration 2. )

RECORDING A-8.33

(or POWER setting)

Illustration 1:

Correct setting

Backup

Longer than 5 minutes

RECORDING A-8.33

(or POWER setting)

Backup

RECORDING A-8.33

(or POWER setting)

Longer than 1 minutes

Longer than 1 minutes

Illustration 2

ARCHIVE button operation

The transfer of data, for backup purposes, from the unit’s
HDD to a peripheral recording device is performed in fixed
data amounts each time. Data transfer begins when 30MB
is recorded onto the HDD. Accordingly, even if the ARCHIVE
button is lit, there are times when the operation of archive
devices are stopped in order to reduce wear on these de-
vices. To end the backup, please press the ARCHIVE but-
ton one more time as the button remains lit even after the
backup process is finished. The ARCHIVE button will start
blinking when pressed, and will stop blinking when recorded

data has been transferred, thus ending the backup proc-
ess.

Cancelling Backup operation

Press the ARCHIVE button during Backup Recording to
halt operation. The Archive Pointer will be re-positioned to
where operation was stopped, and the next Backup Re-
cording will begin at this point. The unit will halt operation
while the ARCHIVE button is blinking; please wait until the
button’s light stays on.

Individual settings during Backup

operation

Choosing a backup system

Select either “ON” or “OFF” for the ARCHIVE OVERWRITE
setting on the <INITIAL SET UP> menu.The default set-
ting is “OFF”. Use the JOG dial and SHUTTLE ring to check
that settings are as desired. (Refer to page 30.)

a) “OFF”: Data will be added to the storage medium from
the point where previous Backup Recording was completed.

After finishing backup

Default setting

before backup recording

TUE

WED

THU

TUE

capacity

Archive pointer

Archive

pointer

Additional recording from the Archive pointer

(Archive media)

b) “ON”: Data previously recorded on the storage medium
will be over-written and erased.

After backup

recording

Default setting

before backup recording

WED

THU

FRI

TUE

Capacity

Overwriting backup

( Archive media)

This data will be erased.

Auto-eject at the completion of backup

The unit can be set so that the storage medium will be
automatically ejected upon completion of Backup process.
Refer to page 31 for details on the setting procedure.

Besides this setting, the archive medium will be automati-
cally ejected under the following conditions.

• When the archive medium becomes full during One-touch
Backup.
• When the archive medium becomes full during Timer
Backup.
• When the ARCHIVE button is pressed once again, after
operation has been initiated with the ARCHIVE button.
• When a recording malfunction, medium error, or system
error occurs during Backup operation.

Making backups (continued)