Warnings and call out output, Warning, Status countermeasure – MITSUBISHI ELECTRIC DX-TL1600EM User Manual

Page 84: Warnings and their appropriate countermeasures

Advertising
background image

84

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Warnings and CALL OUT output

Warnings and CALL OUT output

Warning

CALL OUT

output

Reference

Canceling

the warning

Status

Countermeasure

HDD FULL

SYSTEM ERROR

REC SYSTEM ERROR

COPY SYSTEM ERROR

ARCHIVE SYSTEM ERROR

RESTORE SYSTEM ERROR

NO SIGNAL

(

Q W E R T Y U I

O P { } q w e r

)

ARCHIVE FULL

HDD NEAR END

The internal hard disk drive
is full when either “STOP” or
“ALARM•PROT” has been
selected in “REPEAT”.

The storage capacity of the
hard disk drive is approach-
ing the value entered into
the HDD capacity setting.

When using the copy or
restore functions, either the
amount of data to be
transferred exceeds the
limits of the storage medium,
or there is no data to be
copied.

An error has occurred in
either the RDD device or
the DDS device.

Visual signal was absent
for over 5 seconds during
recording.

The storage medium in the
backup recording device is
full.

• When the warning is canceled, the unit

will start over-writing the oldest data
remaining in the hard disk drive.

• Archive or copy data as necessary.

• Replace the medium in the backup

recording device.

• Reset the range of backup or copying.
• Replace the archive/copy medium.

• Check the storage medium in the RDD

or DDS device. (Insert medium if there
is none. If medium is present and you
with to use it, undo the write-protection.
If medium is present and you do not
wish to use it, replace the medium.)

• Check whether the unit and camera are

properly connected, and that electricity
is on.

• Check whether the visual signal is

being properly outputted.

• Check whether the unit’s camera

setting is set to an empty channel.

Press the
WARNING
RESET button.

Selectable

Selectable

Selectable

Selectable

Fixed

Fixed

Fixed

Fixed

Fixed

ARCHIVE NEAR END

COPY OVERTAKE

ERROR

ARCHIVE OVERTAKE

ERROR

The limit of the archive
medium's storage capacity
is being reached.

Non-backed up data was
over-written while the HDD
was in Repeat mode.

The HDD is in Repeat mode,
and data which has not been
backed up will be over-written.
(The amount of time remaining
before the unit begins over-
writing is approx. 0.5% of the
time indicated as the possible
recording duration.)

• Replace the medium in the backup

recording device.

• If you do not wish to have the data over-

written, stop recording.

• Change the settings for recording inter-

val and image quality.

(More specifically,

lengthen intervals and lowre image quality.)

• Either turn off

recording or, if the
visual signal has
been restored,
cancel the warning

• Press the

WARNING RESET
button.

• Archive or copy data as necessary.

[The warning will
indicate the number
of the non-functioning
camera.]

COPY R/W ERROR

ARCHIVE R/W ERROR

RESTORE R/W ERROR

SCSI connection error or
system malfunction.

A data-writing error occurred
during backup or copying.

• Confirm that the SCSI cable is properly

connected.

• Restart operation.
• Inspect the HDD/archive/copy device.

Fixed

Fixed

• Inspect the archive/copy device.

54

60-63

14,18,36

19,20

19

60-63

27,28

60-63

27,28

27,28

27,28

60-63

60-63

COPY SIZE ERROR

ARCHIVE SIZE ERROR

RESTORE SIZE ERROR

COPY CHECK MEDIA 1

ARCHIVE CHECK MEDIA 1

RESTORE CHECK MEDIA 1

• If you do not wish to have the data over-

written, stop recording.

• Change the settings for recording inter-

val and image quality.

(More specifically,

lengthen intervals and lowre image quality.)

Press the
WARNING
RESET button.

Press the
WARNING
RESET button.

Press the
WARNING
RESET button.

Press the
WARNING
RESET button.

Press the
WARNING
RESET button.

Press the
WARNING
RESET button.

Press the
WARNING
RESET button.

Press the
WARNING
RESET button.

Press the
WARNING
RESET button.

COPY NEAR

OVERTAKE

ARCHIVE NEAR

OVERTAKE

Warnings and their appropriate countermeasures

Options in the CALL OUT options column:
• Selectable: CALL OUT output can be selected/de-selected on the menu.
• Fixed: a CALL OUT signal is emitted without prior selection of this function using the menu.

Advertising