Various recording settings, Operations english ■ various recording settings, Recording by setting manually timer recording – MITSUBISHI ELECTRIC DX-TL1600EM User Manual

Page 35: Image quality setting, The maximum recording fields setting, Estimated recording time <estd time

Advertising
background image

35

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations

ENGLISH

Various recording settings

This Unit has many settings for various recordings needs. You have to make settings on different pages for normal
recording and timer recording. Please refer to the table below for details. If the channel which is to be operated on
<DEFINE GROUP SETTING> is not set, the warning will appear.

Setting

Recording

Recording by setting manually

Timer recording

Normal recording

Image quality

Maximum

recording

setting

Recording

duration

Recording

camera channel

(CH)

Page

Alarm recording

Page

Normal recording

Page

Alarm recording

Page

IMAGE QUALITY in
<NORMAL REC SETTING>

<NORMAL REC SETTING>

IMAGE QUALITY

MAX REC FIELDS

SELECT REC MODE

HIGH

12.5F

(A)

MAX REC FIELDS in
<NORMAL REC SETTING>

Selected SELECT REC
MODE pattern on
<NORMAL REC SETTING>

IMAGE QUALITY in
<NORMAL REC SETTING>

<NORMAL REC SETTING>

IMAGE QUALITY

MAX REC FIELDS

SELECT REC MODE

HIGH

12.5F

(A)

IMAGE QUALITY in
<A-REC/M-DET SETTING>

MAX REC FIELDS in
<A-REC/M-DET SETTING>

A-REC DURATION in
<A-REC/M-DET SETTING>

DEFINE GROUP SETTING

A-REC DURATION

RECORD ALARM

PRE A-REC

15S

SEP

OFF

A-REC DURATION in
<A-REC/M-DET SETTING>

MAX REC FIELDS in
<A-REC/M-DET SETTING>

IMAGE QUALITY in
<A-REC/M-DET SETTING>

<TIMER PROGRAM> P1

DW START END MODE

WED 09:30 10:00 A-12.5

2 --- --:-- --:-- ------

MODE setting in
<TIMER PROGRAM>

<TIMER PROGRAM> P1

DW

START END

MODE

WED

09:30 10:00

A-12.5

2 --- --:-- --:-- ------

START and END time in
<TIMER PROGRAM>

<TIMER PROGRAM>

DW

START END

MODE

WED 09:30 10:00

A

-12.5Ł

2 --- --:-- --:-- ------

Selected SELECT REC
MODE pattern on
MODE setting
of <TIMER PROGRAM>

Selected RECORD ALARM
setting on
<A-REC/M-DET SETTING>

Selected RECORD ALARM
setting on
<A-REC/M-DET SETTING>

page
13

page
37

page
36

page
36

page
13

page
12

This
page

This
page

page
36

page
36

page
12

page
50

page
50

page
50

page
37

<A-REC/M-DET SETTING>

IMAGE QUALITY

MAX REC FIELDS

DEFINE GROUP SETTING

HIGH

12.5F

<A-REC/M-DET SETTING>

IMAGE QUALITY

MAX REC FIELDS

DEFINE GROUP SETTING

HIGH

12.5F

<NORMAL REC SETTING>

IMAGE QUALITY

MAX REC FIELDS

SELECT REC MODE

HIGH

12.5F

(A)

<A-REC/M-DET SETTING>

IMAGE QUALITY

MAX REC FIELDS

DEFINE GROUP SETTING

HIGH

12.5F

<A-REC/M-DET SETTING>

IMAGE QUALITY

MAX REC FIELDS

DEFINE GROUP SETTING

HIGH

12.5F

DEFINE GROUP SETTING

A-REC DURATION

RECORD ALARM

PRE A-REC

15S

SEP

OFF

<NORMAL REC SETTING>

IMAGE QUALITY

MAX REC FIELDS

SELECT REC MODE

HIGH

12.5F

(A)

DEFINE GROUP SETTING

A-REC DURATION

RECORD ALARM

PRE A-REC

15S

SEP

OFF

DEFINE GROUP SETTING

A-REC DURATION

RECORD ALARM

PRE A-REC

15S

SEP

OFF

Image quality setting

For details please refer to “Setting the image quality” on
page 12.

The maximum recording fields setting

For details please refer to “Setting the maximum recording
fields” on page 13.

Estimated recording time <ESTD TIME>

For details please refer to “Setting the maximum recording
fields” on page 13.

Image quality, Max recording fields, Define group

setting and Alarm recording duration setting

When the ALARM IN terminal is triggered by an alarm sen-
sor and CH. MOTION DETECTION setting, the unit will
switch to its preset recording intervals, and can record at
both the regular recording intervals and another recording
interval. In addition, settings can be made for the record-
ing intervals and image quality used when the ALARM IN
terminal is triggered.

Example: Setting the IMAGE QUALITY to “BASIC” (the
default setting is “HIGH”). Set the MAX REC FIELDS to
“6.25F” (the default setting is “12.5F”). Setting the CAM-
ERA CH.

Q

on the SELECT REC MODE menu as PRI-

ORITY to “5”, CAMERA CH.

5

as PRIORITY to “-” (the

default setting is all “1” ). Setting the A-REC DURATION to

Various recording settings

“5M” (the default setting is “15S”).

To use “PRI” setting, first turn the setting “ALL”

on the “RECORD ALARM” setting. The “FILD” set-
ting will appear.

1. Display the <MENU SETTING> menu. Turn the JOG dial to
A-REC/M-DET SETTING then turn the SHUTTLE ring to the
right.

• The <A-REC/M-DET SETTING> menu will appear.

<A-REC/M-DET SETTING>
@IMAGE QUALITY HIGH

MAX REC FIELDS 12.5F

DEFINE GROUP SETTING
A-REC DURATION 15S

2. Turn the JOG dial to move the cursor to IMAGE QUALITY
and turn the SHUTTLE ring to the right.

• The sub-item will start flashing.

@IMAGE QUALITY HIGH

MAX REC FIELDS 12.5F

DEFINE GROUP SETTING

The image quality settings for NORMAL REC

SETTING have to be set on the same menu. For
details of settings for recordings, please refer to page
12.

Advertising