Major operations and their functions (continued), Camera in connectors, Camera out connectors – MITSUBISHI ELECTRIC DX-TL1600EM User Manual

Page 8: Video out connectors, Ac power socket, Ethernet socket, Rear view 6. rs-232c socket, Alarm in terminals, I/o terminals, Scsi terminal

Advertising
background image

8

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Major operations and their functions (continued)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

CAMERA IN

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

CAMERA OUT

VIDEO OUT

Y/C

CLOCK ADJ

REC

POWER ON

POWER OFF

ALARM OUT

MODE OUT

CALL OUT

CALL OUT GND

GND

GND

DC 5V OUT

MAX 30mA

GND

RS-232C

ETHERNET

RESET

ON

SCSI

SCSI

TERMINATION

GND

GND

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

ALARM IN

OFF

1

3

4

2

7

8

9

5 6

10

1. CAMERA IN connectors

Input connector for signal of camera (BNC connec-
tor).

2. CAMERA OUT connectors

Output connector for signal of camera which is pro-
vided via CAMERA IN (BNC connector).

3. VIDEO OUT connectors

Output connector for video signal to monitor(BNC
connector).

S(Y/C) OUT connector
Output connector for separate Luminance and
Chrominance signal. Output signal with VIDEO OUT
connector at the same time.

4. AC power socket

This socket connects to the power cord. Earth ter-
minal is for safety. Use the 100 - 240V plug with
earth for the power of this unit.

Do not connect the earth terminal of a plug to

gas pipe, water pipe, lightning rod and so on.

5. ETHERNET socket

Use in combination with the PC software DX-PC3.
For further information, please refer to the DX-PC3
user’s manual. Use a 10BaseT cable to connect to
the Ethernet terminal. Please note, however, that
only category 3 and category 5 10BaseT cables can
be used. Please do not connect the unit to a com-
mon network.

Rear View

6. RS-232C socket

This terminal is used to connect to host device
with RS-232C terminal. This unit can be control-
led by the other device through this terminal.

7. ALARM IN terminals

Input terminal for alarm signal.

GND terminals
Input ground terminal for ALARM IN terminal. Use
only the terminal for this unit. It may cause dam-
age or poor connection.

8. I/O terminals

Refer to notes on page 9.

9. SCSI terminal

This terminal is for connecting this unit to other
optional peripheral recording devices.

10. RESET button

When pressed, the present time is erased and ini-
tialized, then the power is turned off.

SCSI TERMINATION switch
When set to “ON”, the internal terminator function
is active, and when set to “OFF”, the function is
provided by the peripheral device. Set it to “ON”
when not connecting to a peripheral SCSI device.

Advertising