Specifications, Specifications english – MITSUBISHI ELECTRIC DX-TL1600EM User Manual

Page 85

Advertising
background image

85

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Specifications

ENGLISH

Specifications

Rated Power Supply:

AC 100-240V 50/60Hz

Rated Input:

1.0 - 0.5A (100-240V)

Color System:

PAL-type color system.

Operating Temperature:

41

°

F-104

°

F (5

°

C to 40

°

C).

Relative Humidity:

Max.80(%)

Altitude:

Max.2000(m)

Dimensions:

425(Width) x 380(Depth) x 113(Height)(mm).

Weight:

7.5kg

Recording System

Digital recording system with JPEG compression method.

Sampling

13.5MHz

Data Compression

JPEG

Compression Unit

Field

Resolution

684 x 288

Recording Device

60GB HDD

Video Input:

16 Input BNC-Connector:

1.0 V(p-p), 75 ohms.

Monitor Output:

S-Connector:

Y-Signal: 1.0 V(p-p), 75 ohms.
C-Signal: 0.286 V(p-p), 75 ohms.

BNC-Connector:

1.0 V(p-p), 75 ohms.

Throughout Output:

16 Output BNC-Connector:

1.0 V(p-p), 75 ohms.

Timer Program:

8programs-Daily start and stop time for one week x3set.

Memory Backup:

Lasts for more than 1 month.

CONNECTORS
POWER ON Input:

Terminal for power ON.

LOW: POWER OFF / HIGH: POWER ON

POWER OFF Input:

Terminal for power OFF.

LOW: POWER OFF

ALARM IN(1-16) Input:

Terminal for starting alarm recording.

CLOCK ADJ Input:

Terminal for adjusting clock.

REC Input:

Terminal for start recording.

GND:

Terminal for ground.

ALARM OUT Output:

Terminal for output while alarm recording is under way.

MODE OUT Output:

Terminal for indication of recording selected mode.

DC 5V OUT Output:

Terminal for DC 5V OUT.

CALL OUT/CALL OUT GND:

Terminal for external warning device.

Rating:
ALARM OUT /

Active:

“Low” Level.

Max. Drive current 7mA DC.

MODE OUT

Non active:

Open.

Max. Voltage +24V DC.

ALARM IN / CLOCK ADJ /

Active:

When terminals are short-circuited

REC

or “Low” Level voltage is applied.

Non active:

Open.

CALL OUT /

Active:

ON.

Max. Drive current 7mA DC.

CALL OUT GND

Non active:

Open.

Max. Voltage +24V DC.

RS-232C

RS-232C (D-SUB 9pin) terminal for connection with personal computer.

SCSI

SCSI2 (Half pitch 50pin) terminal.

Accessories
AC power cord (for U.K / for the Continent)

2

Ferrite core

3

Cable tie

3

Weight and dimensions shown are approximate.
Design and specifications are subject to change without notice.

<Interface circuit inside the unit>

5V

5V

10k

22k

Input
terminal

0.047

µ

F

GND

POWER ON/POWER OFF/
ALARM IN/REC/CLOCK ADJ
Input terminal
• Input Circuit

<Interface circuit inside the unit>

Output terminal

GND terminal

ALARM OUT/MODE OUT Output terminal
• Output Circuit

<Interface circuit inside the unit>

CALL OUT terminal

CALL OUT GND terminal

CALL OUT output terminal
• Output Circuit