Operations english, Initializing menus, Im-check mode setting – MITSUBISHI ELECTRIC DX-TL1600EM User Manual

Page 29

Advertising
background image

29

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations

ENGLISH

3. Turn the JOG dial until the cursor is next to ARCHIVE POINT
RESET and turn the SHUTTLE ring to the right.

• The sub-item will start flashing.

4. Turn the JOG dial until “ON” flashes.

<SERVICE>

POWER FAILURE

@ARCHIVE POINT RESET ON

MENU INITIALIZE OFF
IM-CHECK MODE OFF

5. When the message, “TURN THE SHUTTLE RING >> TO
EXECUTE.” is shown on the screen, turn the SHUTTLE ring
to the right.

• The Archive Pointer is now reset.
• If not executing, turn the JOG dial until “OFF” is shown.

<SERVICE>

POWER FAILURE

@ARCHIVE POINT RESET ON

MENU INITIALIZE OFF
IM-CHECK MODE OFF

TURN THE SHTTLE RING
>> TO EXECUTE.

6. Turn the SHUTTLE ring to the left or press the SET UP
button.

Initializing menus

Selecting “ON” of MENU INITIALIZE in the <SERVICE>
menu initializes the setting ,except for the built-in HDD
and the peripheral recording device.

Example: Setting MENU INITIALIZE to “ON” (the default
is “OFF”).

1. Press the SET UP button to display the <MENU SETTING>
menu.

2. Move the cursor next to SERVICE then turn the SHUTTLE
ring to the right.

• The <SERVICE> menu appears.

3. Turn the JOG dial until the cursor is next to MENU
INITIALIZE and turn the SHUTTLE ring to the left to show
“ON”.

<SERVICE>

POWER FAILURE

ARCHIVE POINT RESET OFF

@MENU INITIALIZE ON

IM-CHECK MODE OFF

4. When “PUSH WARNING RESET KEY THEN ALL MENU
WILL BE INITIALIZED.” appears on the screen, press the
WARNING RESET button.

<SERVICE>

POWER FAILURE
ARCHIVE POINT RESET OFF

@MENU INITIALIZE ON

IM-CHECK MODE OFF


PUSH WARNING RESET KEYŁ
THEN ALL MENU
WILL BE INITIALIZED.

• If not executing, change the sub-item to “OFF” and turn
the SHUTTLE ring to the right.

5. SPLIT 16 screen will be shown on the monitor and all menus
are initialized.

Q

W

T

Y

U

I

O

E

R

P

{

}

q

w

e

r

06-09-2000 12:12:05

• Please note that time date display, timer program setting,
the title of all cameras set in CAMERA TITLE of the <MPX
DISPLAY> menu are not initialized.
• The SELECTED PATTERN setting will be initialized to P1 of
TIMER PROGRAM on the <MENU SETTING> menu. Please
refer to the Menu displays on page 50.

IM-CHECK MODE setting

This function is designed to confirm whether alterations
have been made to the data recorded by the unit.

Example: Setting IM-CHECK MODE to “ON” (the default is
“OFF”).

1. Press the SET UP button to display the <MENU SETTING>
menu.

2. Move the cursor next to SERVICE then turn the SHUTTLE
ring to the right.

• The <SERVICE> menu appears.

3. Turn the JOG dial until the cursor is next to IM-CHECK
MODE and turn the SHUTTLE ring to the right.

• The sub-item will start flashing.

4. Turn the JOG dial until “ON” flashes.

<SERVICE>

POWER FAILURE

ARCHIVE POINT RESET OFF
MENU INITIALIZE OFF

@IM-CHECK MODE ON

5. Turn the SHUTTLE ring to the left or press the SET UP
button.

INFORMATION

To distinguish alterations to recorded data:

• Use the PLAY DEVICE button to select the device
that is to be inspected for alterations.
• Press the PLAY button to begin playback of re-
corded data.
• If an alteration is detected on part of the data during
playback, “

” will appear to the right of the “A” (Alarm

Recording number) in the Time Display. “

” indi-

cates the CAMERA channel of the altered data.

28-10-2001 SUN A

00:00:00 25F 50

%

C16

WARNING: MODIFIED IMAGE
(QWERTYUIOP{}qwer

)

• The displayed “

” and the WARNING display can

be cleared by pressing the WARNING RESET but-
ton.
• This function does not work with the communica-
tion function.

If you don’t use this function, please select the

sub-item “OFF”.

Advertising