Functional Description

http://www.motorola.com/computer/literature

4-7

4

4. Notify the local MPU via interrupt if so enabled.

Triple (or Greater) Bit Error (Cycle Type = Non-Burst Write)

Some of these errors are detected correctly and are handled the same as a
double-bit error. The rest may show up as "no error" or "single-bit error",
both of which are incorrect.

Single Bit Error (Cycle Type = Scrub)

1. Write corrected data to the DRAM.

2. Log the error if not already logged.

3. Notify the local MPU via interrupt if so enabled.

Double Bit Error (Cycle Type = Scrub)

1. Do not perform the write portion of the cycle. (This causes the

location to continue to indicate a non-correctable error when
accessed.)

2. Log the error if not already logged.

3. Notify the local MPU via interrupt if so enabled.

Triple (or Greater) Bit Error (Cycle Type = Scrub)

Some of these errors are detected correctly and are treated the same as a
double-bit error. The rest may show up as "no error" or "single-bit error",
both of which are incorrect.