Error logger register, Error logger register -27, 4error logger register – Motorola MVME1X7P User Manual

Page 275

Advertising
background image

Programming Model

http://www.motorola.com/computer/literature

4-27

4

Error Logger Register

SBE

SINGLE BIT ERROR is set when the last error logged
was due to a single-bit error. It is cleared when a 1 is
written to the ERRLOG bit. The syndrome code reflects
the bit in error. (Refer to the

Syndrome Decoding

section.)

MBE

MULTIPLE BIT ERROR is set when the last error logged
was due to a multiple bit error. It is cleared when a 1 is
written to the ERRLOG bit. The syndrome code is
meaningless if MBE is set.

ERA

This bit provides status for a function that is not currently
used in the MCECC sector.

EALT

EALT indicates that the last logging of an error occurred
on a DRAM access by an alternate (MI

not asserted)

local bus master.

ESCRB

ESCRB indicates the entity that was accessing DRAM at
the last logging of a single- or double-bit error. If ESCRB
is 1, it indicates that the scrubber was accessing DRAM.
If ESCRB is 0, it indicates that the local MC680x0 bus
master was accessing DRAM.

ERD

ERD reflects the state of the local bus READ signal pin at
the last logging of a single- or double-bit error. ERD = 1
corresponds to READ = high and ERD = 0 to READ =
low. ERD is meaningless if ESCRB is set.

ADR/SIZ

1st $FFF4305C/2nd $FFF4315C (8-bits)

BIT

31

30

29

28

27

26

25

24

NAME

ERRLOG

ERD

ESCRB

ERA

EALT

0

MBE

SBE

OPER

R/C

R

R

R

R

R

R

R

RESET

0 PLS

0 PLS

0 PLS

0 PLS

0 PLS

X

0 PLS

0 PLS

Advertising