5.12.12.1

Margin Control Subpage (Sub Page 1 of Mode Page 19)

The Margin Control subpage (see Table 5-74) contains parameters that set and report
margin control values for usage between the initiator/target pair on subsequent
synchronous and paced transfers.

A MODE SELECT command will return the current settings for the initiator/target
pair. Fields that are not implemented will be reported as zero.

Table 5-74

Margin Control Subpage (01h)

Table 5-75

Field Descriptions

Bit

Byte

7

6

5

4

3

2

1

0

0

Reserved

1

Driver Strength

Reserved

2

Drive’s Asymmetry

Driver Precompensation

3

Drive’s Slew Rate

Reserved

4

Reserved

5

Reserved

6

Reserved

7

Vendor Specific

8

Reserved

9

Reserved

10

Reserved

11

Reserved

12

Reserved

13

Reserved

14

Reserved

15

Reserved

Field

Description

Driver

Strength

The DRIVER STRENGTH field indicates the relative amount of driver source cur-

rently used by the driver. The Driver Strength field affects both the strong and week

drivers. A larger value indicates more driver source current.

Driver Pre-

compensation

The DRIVER PRECOMPENSATION field indicates the relative difference between

the weak driver and the strong driver amplitudes when precompensation is enabled.

A larger value indicates a larger difference between the weak and strong amplitudes.

Driver

Asymmetry

The Driver Asymmetry field indicates the relative difference between the amplitudes

of asserted and negated signals launched from the driver. A larger value indicates a

relatively stronger asserted signal compared to the negated signal.

Driver Slew

rate

The DRIVER SLEW RATE field indicates the relative difference between the asser-

tion and negation magnitudes divided by the rise or fall time. A larger value indicates

a faster slew rate.